1. Water level and water quality
Step 1 · Check water level and leaks
Click to open instructions, photos / video
↓
|
Pump leaks ↓ Possible water pump failure Step 9 → Record the leak. |
Below 80%; no leaks ↓ Step 1.1 → |
80% full; no leaks ↓ Step 2 → |
Step 1.1 · Fill water and run a task
Click to open instructions, photos / video
|
Problem solved ↓ Problem solved |
Problem remains ↓ Step 2 → |
Step 2 · Check whether water is clean
Click to open instructions, photos / video
|
Clean ↓ Step 3 → |
Not clean ↓ Step 2.1 → |
Step 2.1 · Change water and run a task
Click to open instructions, photos / video
|
Problem solved ↓ Problem solved |
Problem remains ↓ Step 3 → |
2. Flow speed and water hoses
Step 3 · Run the flow speed test
Click to open instructions, photos / video
↓
|
At least 3 L/min ↓ No error during a task → Problem solved Error still appears → Step 8 → |
0–2.99 L/min ↓ Returning after Step 6 activated the pump → Step 7 → Otherwise, already checked hoses in Step 4 → Step 5 → First test → Step 4 → |
Step 4 · Check hoses at pump, radiator and laser tube
Click to open instructions, photos / video
|
Hoses in good positions ↓ Step 5 → |
Adjusted and realigned ↓ Repeat the flow test: Step 3 → |
Bent; cannot adjust ↓ Possible hose length or leakage issue Step 9 → Take photos of affected hoses. |
3. Water pump checks
Step 5 · Enable Pump and check for pumping / vibration
Click to open instructions, photos / video
↓
|
Pump runs ↓ 0 L/min → Step 7 → More than 0 but less than 3 L/min → Possible weak pump; replacement needed Step 9 → Record the low flow result and confirm hoses were checked. |
Pump does not run ↓ Step 5.1 → |
Step 5.1 · Exit pump protective mode
Click to open instructions, photos / video
Power off and unplug for at least 1 minute, then restart and enable Pump.
|
Pump runs; problem solved ↓ Problem solved |
Pump runs; flow still abnormal ↓ 0 L/min → Step 7 → More than 0 but less than 3 L/min → Possible weak pump; replacement needed Step 9 → Record the low flow result and confirm hoses were checked. |
Pump still does not run ↓ Step 6 → |
Step 6 · Try to activate the pump physically
Click to open instructions, photos / video
|
Pump now runs ↓ Repeat the flow test: Step 3 → |
Pump still does not run ↓ Possible failed pump; replacement needed Step 9 → Record the pump while Pump is enabled on the panel. |
4. Flow sensor and factory reset
Step 7 · Replug flow sensor cable and repeat flow test
Click to open instructions, photos / video
↓
|
At least 3 L/min ↓ No error during a task → Problem solved Error still appears → Step 8 → |
0 L/min ↓ Step 8 → |
More than 0; less than 3 L/min ↓ Next action not specified in the source article |
Step 8 · Reset to Factory and repeat flow test
Click to open instructions, photos / video
|
At least 3 L/min ↓ No error during a task → Problem solved Error still appears → Possible mainboard issue; flow sensor less likely Step 9 → |
0 L/min ↓ Possible mainboard or flow sensor issue Step 9 → |
More than 0; less than 3 L/min ↓ Next action not specified in the source article |
When Step 8 leads to support, take photos of the flow test result and the error during a task.
Step 9 · Report to your reseller or FLUX Support
Click to open instructions, photos / video
Include the photos or videos requested by the branch you followed. Contact Customer Service →
Step instructions, photos and videos
Step 1 - Check if the water is 80% full: — open instructions
Step 1 - Check if the water is 80% full:
← Back to this step in the flowchart
| Note: If your machine doesn't have enough water, the flow speed may be lower, and the water pump may enter protective mode and won't be able to be turned on for a few minutes. |
- Open the water pump cover with the Torx screwdriver and check if the water is 80% full.
- Check if there is any leakage on the pump.
Step 1.1 - Fill up the water: — open instructions
Step 1.1 - Fill up the water:
← Back to this step in the flowchart
- Please refer to the video in the link below to add more water to the pump.
Cooling Water Replacement
- After filling up the water, please check if the problem is solved by running a random task.
Step 2 - Check if the water is clean: — open instructions
Step 2 - Check if the water is clean:
← Back to this step in the flowchart
Dirty water will affect the flow of the water. Make sure to have clean water in the system.
Step 2.1 - Change water: — open instructions
Step 2.1 - Change water:
← Back to this step in the flowchart
- Please refer to the video in the link below to change the water.
Cooling Water Replacement
- After changing the water, please check if the problem is solved by running a random task.
Step 3 - Test the flow speed: — open instructions
Step 3 - Test the flow speed:
← Back to this step in the flowchart
Please perform a flow speed test and see if the value is normal.
(Machine Panel > Machine > Hardware Settings > Flow Speed Test )
Step 4 - Check the water hoses: — open instructions
Step 4 - Check the water hoses:
← Back to this step in the flowchart
If you have a bad value that is bigger than 0L/min and smaller than 3L/min, this indicates your whole system works okay, but the flow speed is too low and this might be caused by water hoses being bent or kinked.
-
Bent hose: (Bad example)
There are three locations to check for water hoses.
(If your hoses are bent or kinked, please try to adjust their positions.)
-
Location #1 - Water pump:
-
Location #2 - Radiator & Cooling fans:
-
Location #3 - Laser tube:
(The back cover has to be opened first.)
Step 5 - Check if the water pump can be activated. — open instructions
Step 5 - Check if the water pump can be activated.
← Back to this step in the flowchart
Please refer to the video below for how to perform the test.
If a water pump is activated successfully, the water inside the tank will be pumped, and you should feel it vibrating when touching it.
-
How to check:
(Machine panel > Control > Pump > Check the pump at the back)
Step 5.1 - Try to exit the protective mode of the pump — open instructions
Step 5.1 - Try to exit the protective mode of the pump
← Back to this step in the flowchart
If the water level is not high enough while the water pump is running, it will enter protective mode, meaning it will not be able to run.
- To exit this mode, turn off and remove the power cord. Wait at least 1 minute.
-
After 1 minute, turn on the machine to test if the water pump can be activated.
(Machine panel > Control > Pump > Check the pump at the back)
Step 6 - Try to activate the water pump physically: — open instructions
Step 6 - Try to activate the water pump physically:
← Back to this step in the flowchart
Please take the following actions to try to activate the water pump.
- Unplug and replug the water pump's cable.
(Refer to the diagram if your PCB board is not the same as the photo.)
- Enable the pump on the Maintain page first and pinch both hoses at the pump's inlet and outlet to apply pressure with your fingers.
(It could be the stuck air in the system that the pump is not able to push.)
- Enable the pump on the Control page first and hit it with your hand.
(It could be the pump's turbine being stuck, causing the pump not to pump water.)
Step 7 - Replug the cable of the flow sensor: — open instructions
Step 7 - Replug the cable of the flow sensor:
← Back to this step in the flowchart
A bad flow speed may be affected by improper connection of the flow sensor.
Step 8 - Reset to the Factory: — open instructions
Step 8 - Reset to the Factory:
← Back to this step in the flowchart
Please reset the machine to the factory and run a flow speed test.
(The purpose is to see if this is firmware issue related or hardware issue related.)
- Reset the machine to the factory.
(Main Page > Machine > Next page > Reset to Factory > Yes)
- After the reset, run a flow speed test again.
(Refer to Step 3)
Step 9 - Report to the local reseller or FLUX Support: — open instructions
Step 9 - Report to the local reseller or FLUX Support:
← Back to this step in the flowchart
- Please follow the instructions in the link below to properly report an issue to your local reseller or FLUX support. [Contact Customer Service]
*The collected information such as photos or videos that show the problem of your machine in this article will be necessary to be shared with the reseller or FLUX Support.