Recommended Frequency
Once an operation, especially for cutting works with a lot of debris.
To avoid the possible fire hazard due to the left of small pieces of cutting materials on or beneath the honeycomb table, it is recommended to clean the honeycomb table right after use.
Preparation Items
- Vacuum cleaner or brush
- Paper towel or tissue paper
- Air conditioner coil foaming cleaner (Optional)
Maintenance Steps
1. Take the honeycomb table out
- The mesh part of the honeycomb table is relatively sharp, so please be careful when holding it.
- Move the laser head to the upper right of the working range. If the laser head cannot be moved, go to the “MAINTENANCE” on the screen > “Motors” to release the motors.
- Perform a 2-second press on the "Autofocus" button to do the Z-axis homing to avoid hitting the probe while taking the honeycomb table out.
- Lift up the honeycomb table handles, hold the two sides of the honeycomb table, and pull it out.
2. Clean the honeycomb table
- Use a vacuum cleaner or brush to clean the large residue and dust
- Spray the honeycomb table with the air conditioner coil foaming cleaner
- Wait for the tar oil to soften, then wipe it with a paper towel or tissue paper to remove the tar.
3. Put the honeycomb table back
- Place the honeycomb table at a 45-degree angle into the chassis and lay it flat.
Comments
0 comments
Please sign in to leave a comment.